Safety switch with interlock and integrated evaluation electronics Holding force up to 6500 N Up to 20 switches in series Cross-circuit monitoring 2 safety outputs (semiconductor outputs) Category 4 / PL e according to EN ISO 13849-1 With 2 M12 connectors Multicode escape release, 105 mm long Approach direction A (as delivered)
Item from plant decommissioning
Item from plant decommissioning
Electrical connection values
Fusing external (operating voltage UB) 0.25 ..8 A external (operating voltage UCM) 0.5 ..8 A Power consumption Magnet 11 W Operating voltage DC UB 24 V DC -15% ..+15% reverse polarity protected, regulated, residual ripple < 5 %, PELV LED1, LED2 24 V DC -15% V DC ..+10% V DC EMC protection requirements according to EN IEC 60947-5-3 Utilization category DC-13 24V 200mA Magnet operating voltage DC UCM 24 V DC -15% ..+10% reverse polarity protected, regulated, residual ripple < 5 %, PELV Magnet duty cycle ED 100 % Risk time according to EN 60947-5-3 max400 ms Risk time according to EN 60947-5-3, extension for each additional device max5 ms Switching load according to UL 24V DC, Class 2 Protection class EN IEC 61140 III Current consumption IB 80 mA ICM 450 mA Test pulse duration max1 ms Pollution degree (external, according to EN 60947-1) 3 Signal output OUT Type of output Semiconductor output, p-switching, short-circuit proof Output voltage OUT 0.8xUB ..UB V DC Output current OUT 1 ..50 mA Safety outputs OA / OB Type of output Semiconductor outputs, p-switching, short-circuit proof Output voltage HIGH U(OA,OB) UB-1.5V ..UB V DC LOW U(OA,OB) 0 ..1 V DC Output current per safety output 1 ..200 mA Discrepancy time of both safety outputs max10 ms Turn-on time safety outputs 400 ms Residual current Ir max0.25 mA
Fusing external (operating voltage UB) 0.25 ..8 A external (operating voltage UCM) 0.5 ..8 A Power consumption Magnet 11 W Operating voltage DC UB 24 V DC -15% ..+15% reverse polarity protected, regulated, residual ripple < 5 %, PELV LED1, LED2 24 V DC -15% V DC ..+10% V DC EMC protection requirements according to EN IEC 60947-5-3 Utilization category DC-13 24V 200mA Magnet operating voltage DC UCM 24 V DC -15% ..+10% reverse polarity protected, regulated, residual ripple < 5 %, PELV Magnet duty cycle ED 100 % Risk time according to EN 60947-5-3 max400 ms Risk time according to EN 60947-5-3, extension for each additional device max5 ms Switching load according to UL 24V DC, Class 2 Protection class EN IEC 61140 III Current consumption IB 80 mA ICM 450 mA Test pulse duration max1 ms Pollution degree (external, according to EN 60947-1) 3 Signal output OUT Type of output Semiconductor output, p-switching, short-circuit proof Output voltage OUT 0.8xUB ..UB V DC Output current OUT 1 ..50 mA Safety outputs OA / OB Type of output Semiconductor outputs, p-switching, short-circuit proof Output voltage HIGH U(OA,OB) UB-1.5V ..UB V DC LOW U(OA,OB) 0 ..1 V DC Output current per safety output 1 ..200 mA Discrepancy time of both safety outputs max10 ms Turn-on time safety outputs 400 ms Residual current Ir max0.25 mA
| Technical characteristic | Value |
|---|---|
| Condition | Used |
| Age rating | No age restriction |
| Model | CET2-AR-CRA-CH-50F-SG-C2312-109941 |
| Manufacturer | EUCHNER GmbH + Co. KG |
| Content | 1 piece |
| Weight | 2000 g |
| Net weight | 1300 g |
| Item ID | 1234589071 |
| Item ID | 1234589071 |
EUCHNER GmbH + Co. KG
EUCHNER CET2-AR-CRA-CH-50F-SG-C2312-109941 Non-contact safety switch 5 kN
Item number VN-23551
EAN
Condition Used
Available quantity
EUR 193.01
*
Content
1 piece
Unit price
€193.01 / piece
immediately available